Rev Australasia V2.3 12/04
51 51
3.2.13. Re-Send Last Tag
In case port type is set to RS232 the reader re-sends last tag read according to the
currently selected ID-Code format settings. In serial bus mode, where port type is set
to either RS422 or RS485, the reader transmits the first read result stored in the ID
code buffer out the serial port, according to the currently selected ID-Code format
settings
8
. This way the readers can be polled to request tag data from the readers
connected to the bus, as the readers using serial bus mode then do not automatically
send tag data upon successful detection.
Command: r
Parameters: none
Readers Response - No Tag Available:
wo/Command Prompt
9
w/Command Prompt
9
<CR><LF>
*E00<CR><LF>
10
<CR><LF>
*E00<CR><LF>
10
<LF>
>
3.2.14. Retrieve ID-Code Buffer
Retrieves the entire ID-Code buffer.
Command: G
Parameters: none
Readers Response – Tag Available:
The Reader transmits the entire ID-Code memory according to the current serial ID-
Code format settings
9
. If the command prompt is enabled, the readers response is
trailed by:
<LF>
>
Readers Response - No Tag Available:
wo/Command Prompt
11
w/Command Prompt
11
<CR><LF>
*E00<CR><LF>
12
<CR><LF>
*E00<CR><LF>
12
<LF>
>
3.2.15. Clear ID-Code Memory
Deletes the entire ID-Code memory.
9
See section 3.2.5. Serial ID-Code format settings.
10
Error Message: Command couldn't be executed!
11
See section 3.2.5. Serial ID-Code format settings.
12
Error Message: Command couldn't be executed!