data capture process either into scale heads, or the computer that you are using. In most
cases the software has a means of coping with this.
(b) Electrical Machinery - Most 240 volt AC operated electrical machinery will not interfere
with the Panel Reader’s electrical signals. However, machinery that is electrically
controlled by electronic methods, such as motor speed controls, light dimmers, and solid
state relays can produce high frequency emissions that can cause interference. When the
Panel Reader is being trial installed, the user should run all the machinery in the vicinity
to ensure that all potentially interfering sources do not exist. When wiring an AC mains
operated power supply for use with the Panel Reader, avoid wiring the AC connection to
the same phase as such electric machinery is wired.
(c) Other Eartags
- If the Panel Reader is being installed in a location where eartagged
animals will exist on all sides of the Reader (such as a feeder), precautions must be taken
to ensure that only animals within the designated reading zone are read. This can usually
be achieved by positioning sheet metal, or mesh in an appropriate location between the
reader and the area where you want to “block” reading. If you do have multiple eartags
simultaneously present in the read zone of the antenna, either eartag might read, both
eartags might read, or neither eartag might be read.
(d) Other Readers - Operating multiple Panel Readers within close proximity, or operating a
mobile hand-held reader nearby a Panel Reader, can reduce the read range of all readers
present. In some cases this can totally inhibit reading of all readers. If multiple readers are
to be used in proximity to each other, it will be necessary to synchronize the readers.
Synchronization will require additional hardware equipment. Please call Allflex for
assistance with synchronization. Allflex Australia – 07 3245 9100. Allflex New Zealand -
06 356-7199.
Once a suitable location site and installation method have been determined, the Panel Reader
can be permanently mounted in position using the ¼” (6mm) pre-drilled mounting holes. If it
is necessary, alternate or additional mounting holes may be drilled by the user, using caution
to drill only within the rectangle defined by the existing mounting holes. Standard steel bolts
will not compromise Panel Reader performance.
Note - The Panel Reader is designed to be completely water-tight. While not intended for
installation immersed in water, contact with water spray, such as heavy rain or power washers
is acceptable.
Caution! - Ensure that the mounting structure itself is sufficiently strong enough to endure
impact by animals that will come into contact with it. Do not rely on the Panel Reader to
contribute to the structural strength of the installation.