Allflex AFX-100 Manual do Utilizador Página 44

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 53
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 43
Rev Australasia V2.3 12/04
44 44
3.2.3. Serial Hardware Settings
Changes serial port hardware parameters. Unassigned bit values are always deleted to
zero!
Write Command: S
Read Command: s
Write Command Parameters: xxxx<CR>, where xxxx is a hexadecimal value.
Readers Response:
wo/Command Prompt
3
w/Command Prompt
3
<CR><LF>
*S-xxxx<CR><LF>
<CR><LF>
*S-xxxx<CR><LF>
<LF>
>
Write Command Parameter Bit Assignments:
BIT # FUNCTION
0 - 1 Port Type
2 - 7 Not used
8 - 10
(0=LSB)
Bit Rate
11 Data Bits
12 - 13 Parity
14 Flow Control
15 Not used
0000000000000000b
||||||||||||||||
||||||||||||||++--> Port Type (00 = *RS232, 01 = RS422, 10 = RS485)
||||||||++++++----> Not used
|||||+++----------> Bit Rate (000 = 300 baud, 001 = 1200 baud)
||||| (010 = 2400 baud, 011 = 4800 baud)
||||| (100 = *9600 baud, 101 = 19200 baud)
||||| (110 = 38400 baud, 111 = 57600 baud)
||||+-------------> Data Bits (1=*8 Bits, 0=7 Bits)
||++--------------> Parity (000= *none, 01 = even, 10 = odd)
|+----------------> Flow Control (1=X
ON/XOFF, 0=*none)
+-----------------> Not used
3
See section 3.2.5. Serial ID-Code format settings.
Vista de página 43
1 2 ... 39 40 41 42 43 44 45 46 47 48 49 ... 52 53

Comentários a estes Manuais

Sem comentários