should connect to Pin A on the military connector. Therefore touch the second test lead
against Pin 2, if the cable is correctly joined you will hear the meter beep and see the dial or
display show zero, or almost zero ohms.
Use the table above and use the same process to also check the connections for Pin 3 and
Pin 5 on the D connector and ensure that the cable is not broken. If you test any of the 3
wires and find that they do not connect, you should use a replacement cable, or, open the
military connector and re-solder any wires that you can see have become detached.
If you can see the cable is broken at some point in the centre, you can make a temporary
repair by stripping back the 3 relevant wires, twisting each one together separately and
sealing with insulation tape. You will know what coloured wires to join by opening up the
military connector and seeing the 3 wires that terminate. (As a standard Allflex usually uses
White, Green and Yellow).
Apart from the cable breaking (open circuit), it could happen that the cable gets exposed to
direct rain and that water is shorting out some of the pins. To test this, insert the paper clip
to Pin 2 and then test to Pin A, B and D on the other end. As you see from the table above,
the cables should only join from one point on one end and to a specific point on the other
end. If you notice that there is a join between multiple points this indicates that there is a
short circuit. Open the military connector and see if it has water inside and spray with water
dispersant spray if required.