2 SPECIFICATIONS
Full ISO 11784 and full ISO 11785 including annex C
for FDX-A (Destron, Trovan and encrypted Avid),
FDX-B and HDX.
Temperature scanning with TD and BT implants
Graphical display 128x64 dots
2 keys
Buzzer and Vibrator
USB port and optional Bluetooth® module
Serial emulation (CDC class) from 1200bps to
115200bps.
Class 2 (up to 10m)
Serial Port Profile (SPP).
7.2VDC – 700mAh NiMH rechargeable.
1 month
without reader using @ 20°C
280 x 83 x 55 mm (11 x 3.27 x 2.17 in)
-10°C to +40°C (+14°F to +104°F)
-30°C to +70°C (-22°F to +158°F)
Distance for implants HDX:
@ orientation (°)
Up to 16 cm (6.3 in) @ 0° [Figure 1]
Up to 10 cm (4 in)
@ 90° [Figure 2]
Distance for implants FDX-A Destron (Fecava
version) technology:
@ orientation (°)
Up to 6 cm (2.4 in)
@ 0° [Figure 1]
Up to 4 cm (1.6 in)
@ 90° [Figure 2]
Distance for implants FDX-A Trovan technology:
@ orientation (°)
Up to 1 cm (0.4 in) @ 0° [Figure 1]
Up to 2 cm (0.8 in) @ 90° [Figure 2]
Distance for implants FDX-A Encrypted technology:
@ orientation (°)
Up to 4.5 cm (1.7 in) @ 0° [Figure 1]
Up to 2.8 cm (1.1 in)
@ 90° [Figure 2]
Distance for implants FDX-B:
@ orientation (°)
Up to 13 cm (5.1 in) @ 0° [Figure 1]
Up to 8 cm (3.15 in)
@ 90° [Figure 2]
Figure 1 - implants perpendicular to the reader.
Figure 2 - implants parallel to the reader.